Fire Sprinkler System Inspection Testing and Maintenance

Fire Sprinkler System Inspection Testing and Maintenance

Views : 714
Update time : 2023-05-11 16:43:24


1. Check whether the test device at the end of the sprinkler pipe network is normal (whether the water pressure and flow meet the requirements).

2. Check whether the test water flow indicator is sensitive, whether the alarm is accurate, whether the reset is normal, whether there is a display in the fire center.

3. Check whether the sprinkler and pipeline are in good condition, and whether there is any hidden danger.

4. Check whether each valve is in the normal open state, test whether the floor signal valve switch is flexible, and whether the fire center has a closing signal display.

5. Check and maintain the water pump adapter of the sprinkler system to make sure integrity and no leakage.

6. Test regularly whether the safety pressure relief valve is sensitive and reliable, and check whether the water hammer absorber works effectively.

7. Check if the automatic exhaust valve of the spray riser works normally.

8. Check and test whether the wet system alarm valve and hydraulic alarm bell are in good condition, whether the spray pump is started, and whether the display of the fire center is accurate.

9. Check whether the valve is flexible and effective regularly. If the valve is not closed tightly or can’t be used flexibly, it should be repaired in time. If the contact surface of the valve is defective, it needs to be ground and replaced if it can’t be repaired. Add oil regularly to the bolts of the rotating parts of the valve.

10. Check whether the turning on and off of the check valve is flexible and effective.

11. Check the fire sprinkler system pipe network regularly, replace severely corroded pipes, and for pipelines with peeling paint, remove the rust, and paint the anti-rust paint and marking paint.
Related News
Read More >>
What is Fire Hose? What is Fire Hose?
Oct .13.2023
A fire hose is a highly pressurized hose that is used to bring water to the fire. It may also transport flame retardants. Fire hoses can be attached to either a fire engine or a fire hydrant, and the pressure is between 800 and 2000 kPa. For reasons of fire safety, it's quite important to have a fire hose inspection as well as all fire protection equipment tested.  If, during a fire emergency, the fire hose fails it could have disastrous results.
Addressable Explosion-proof Fire Alarm System Introduction Addressable Explosion-proof Fire Alarm System Introduction
Aug .08.2023
The Explosion Proof range of products has been designed to provide protection against explosions and products to ensure that all major advantages of high-quality fire detection technology can be safely exploited in industrial and hazardous environments. Many difficult sites such as metal, paint, pipelines, chemical, pharmaceutical, oil refineries, and other installations are vulnerable to the risk of explosion. In order to protect the assets and people, they need special solutions for fast and reliable fire detection.
Emergency Lighting System Installation Guide Emergency Lighting System Installation Guide
Jul .20.2023
Emergency lighting system is divided into centralized controlling and non-centralized controlling type, or centralized power supply and non-centralized power supply type. This article talks about emergency lighting system, power supply, emergency light controller installation guide.
Fire Alarm System Device Inspection and Maintenance Fire Alarm System Device Inspection and Maintenance
Jul .05.2023
Installing fire protection facilities and carry out regular maintenance are significant. This article talks about the inspection and maintenance of linear beam smoke detector, aspirating smoke detector, flame detector, manual call point, and strobe sounder.